iopposter.blogg.se

Brocade san switch replacement procedure
Brocade san switch replacement procedure






brocade san switch replacement procedure
  1. #Brocade san switch replacement procedure upgrade
  2. #Brocade san switch replacement procedure password
  3. #Brocade san switch replacement procedure zip
  4. #Brocade san switch replacement procedure windows

Send the output of switch> supportsave from all the switches involved in the issue.

#Brocade san switch replacement procedure zip

After collecting the logs, the user can zip the directory and upload to NetApp.

#Brocade san switch replacement procedure password

  • Next, perform the same steps as above, this time using the username and password of the UNIX host, specifying SCP for the protocol, and specifying the name of the directory created to collect the logs.
  • The easiest method is by using SCP. Verify that SCP is installed on the host, and a directory has been created on the root volume of the host.
  • #Brocade san switch replacement procedure windows

  • If a Windows host is not available to FTP, a UNIX host can be used as well.
  • brocade san switch replacement procedure

    Saving support information for switch:brocade200e-rtp, module:FABRIC. Saving support information for switch:brocade200e-rtp, module:TRACE_NEW. The term Enterprise version specifically refers to the Brocade Enterprise SAN Switch Module for IBM Eserver. Throughout this document, the term switch module generically refers to both types of switch modules. Saving support information for switch:brocade200e-rtp, module:TRACE_OLD. Brocade Enterprise SAN Switch Module for IBM Eserver BladeCenter and the Brocade Entry SAN Switch Module for IBM Eserver BladeCenter. Saving support information for switch:brocade200e-rtp, module:RAS.

    brocade san switch replacement procedure

  • Press Enter the output files will be sent to the destination:.
  • Enter the name of the directory you created on the FTP root for case number and the specific switch:.
  • Specify the transfer protocol, in this case ftp or sftp:.
  • Password:, or just press enter for “blank” User Name:, or just press enter for “blank”

    brocade san switch replacement procedure

  • Enter the credentials for SFTP, or leave it blank for an anonymous FTP:.
  • Enter the IP address or host name of the FTP server:.
  • At the command prompt, type y to proceed:.
  • There will be two trace dump files transferred after running this command. Note: The supportsave transfers the existing trace dump file first, then automatically generates and transfers the latest one. This command collects RASLOG, TRACE, supportShow, core file, FFDC data, and other support information from both active and standby CPs, and then transfer them to the FTP/SCP/SFTP server or a USB device.

    #Brocade san switch replacement procedure upgrade

    Brocade Fabric OS Upgrade Guide, 8.1.0 ''. Upgrading from Upgrade procedure Brocade Fabric OS Upgrade Guide, 8.1.0. Brocade 7840 Extension Switch Brocade Gen 5 (16-Gbps) Directors. Once a FTP server with the named folder has been created, log into the Brocade switch and run the supportsave command: Brocade M6505 blade server SAN I/O module Brocade 6542 blade server SAN I/O module.Zone configuration can be saved by using the below commandīy running the cfgsave command the newly created zones will only get saved but won't be activated. In one switch there can be only one Active Zoning Configuration. Once the zone is created we need to save the active zone configuration. In this case we would create a zoning between server HBA and 3PAR array Front end ports. And LUNs need to be allocated from 3PAR array to that server. Zoning is the process in which a path is established between 2 connected devices so that the data transfer takes place between them securely.įor example consider a server and 3PAR array which are connected to the same SAN fabric. Alias will be created by using the below command.įor Example: alicreate "a_SERVER1_PROD_FAB11", "50:01:43:80:17:87:F7:A4" This is to give the easy naming convention for the WWPN. Once the device gets connected the communication will start between the zone members.Īlias will be created for the easy understanding and management. However zoning can be done using CLI even if the device is not connected to the SAN switch (This is not the best practice). If the device is connected to the SAN switch and powered off then WWPN wont be showing up in the Webtool or in CLI.








    Brocade san switch replacement procedure